LaCie 12big Rack Fibre 8 Troubleshooting & Problem Solving
User Manual page 61
The audible alarm can be muted by pressing the Mute button on the
OPS panel. Automatic muting will take place after two minutes if the
mute switch is not manually operated.
When the alarm is muted it will continue to sound with short intermit-
tent beeps to indicate that a problem still exists, It will be silenced
when all problems are cleared.
Table 15 - Alarm Conditions
Status Severity Alarm OPS Panel LED
PCM Alert – Loss of DC power from a single
PCM.
Fault – No Loss of Redundancy. S1 Module Fault.
PCM Alert – Loss of DC power from a single
PCM.
Fault – Loss of Redundancy. S1 Module Fault.
PCM Fan Fail. Fault – Loss of Redundancy. S1 Module Fault.
SBB Module detected PCM Fault. Fault. S1 Module Fault.
PCM Removed. Configuration Error. None Module Fault.
Enclosure Configuration Error. Fault – Critical. S1 Module Fault.
Low Warning Temperature Alert. Warning. S1 Module Fault.
High Warning Temperature Alert. Warning. S1 Module Fault.
Over Temperature Alarm. Fault – Critical. S4 Module Fault.
I2C Bus failure. Fault – Loss of Redundancy. S1 Module Fault.
OPS Panel Communication Error (I2C). Critical Fault. S1 Module Fault.
RAID Error. Fault – Critical. S1 Module Fault.
SBB Interface Module Fault. Fault – Critical. S1 Module Fault.
SBB Interface Module Fault – No function-
ing modules remaining.
Fault – Critical. S4 Module Fault.
SBB Interface Module Removed. Warning. None Module Fault.
Drive Power Control Fault. Warning – No loss of drive power. S1 Module Fault.
Drive Power Control Fault. Fault – Critical – loss of drive power. S1 Module Fault.
Drive Removed. Warning. None Insufficient Power Available.